CodingBox Nyaraka

SFP28

Timu yetu inashughulikia tafsiri. Makala hii haipatikani kwa Kiswahili kwa sasa, kwa hiyo inaonyeshwa kwa Kiingereza.

SFP28 carries a single 25 Gb/s lane in the SFP footprint. It emerged from the 100GbE work — one lane of a 4×25G QSFP28 — and made 25GbE the natural server uplink, replacing 10G at nearly the same cost per port.

Key facts

Lanes × rate1 × 25.78 Gb/s (NRZ)
Total25G
ConnectorLC duplex; SFP28 DAC/AOC
Supply3.3 V
Applications25GBASE-SR/LR/ER (IEEE 802.3by), 32GFC, server-to-leaf links

Specifications

  • SFF-8402SFP+ 1X 28 Gb/s Pluggable Transceiver Solution (SFP28): the mechanical and electrical definition of SFP28.
  • SFF-8432Module and Cage (shared with SFP+).
  • SFF-8472Management Interface.
  • IEEE 802.3by — the 25GbE PHY and the 25GAUI electrical interface.

Management interface

Two-address SFF-8472 as with SFP+ (A0h identity, A2h diagnostics), with 25G rate and interface codes from SFF-8024. Forward error correction options (no FEC / BASE-R / RS-FEC) matter at 25G: a mismatch between host and module settings is a classic cause of a link that will not come up.

Compatibility notes

  • Backward compatible: an SFP28 port accepts SFP+ and SFP modules at their own rates.
  • Four SFP28 links are the breakout of one QSFP28 port (4×25G) — see QSFP28.

In CodingBox

Fully supported per SFF-8472 — identity, DDM with thresholds, editing and writing with checksum recalculation. SFP28 identity fields are decoded with the 25G codes so the Check transceiver screen reports the correct interface.


Ukipata kasoro au kosa katika makala hii, chagua sehemu husika kisha ubonyeze Ctrl+Enter ili .